Slitting line machine supplier by canwindg.com: Power Quality and Distribution Transformers – The efficiency of distribution transformer substations is significantly affected by power quality. These transformers, which are critical components of the electrical distribution system, convert high-voltage electricity into lower voltage levels suitable for end-use applications. The performance and efficiency of these transformers largely depend on the quality of power they receive. Poor power quality, characterized by voltage sags, swells, harmonics, and flicker, can lead to increased losses in power distribution transformers. These losses can be categorized into two types: core losses and copper losses. Core losses occur due to variations in the magnetic field within the transformer’s core, while copper losses occur due to the resistance of the transformer’s windings. Both these losses are exacerbated under conditions of poor power quality, leading to decreased efficiency of the transformer. Find more info at https://www.canwindg.com/products-detail-127763.
When is it not allowed to adjust the tap changer of the transformer on-load voltage regulating device? The on-load voltage regulating device is a common accessory equipment of the transformer, which is used to adjust the transformation ratio when the transformer is running, so as to achieve the purpose of adjusting the output voltage. When using the on-load pressure regulator, the following points need to be paid attention to: It is not allowed to operate under live conditions: because the transformer is working under live conditions, the tap changer of the on-load voltage regulating device will have an arc when it is adjusted, so it is not allowed to operate the tap changer under live conditions. Frequent adjustments are not allowed: frequent adjustments to the tap changer of the on-load tap changer may cause damage to the tap changer or poor contact, thereby affecting the normal operation of the transformer.
Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.
We have provided OEM/ODM china cut to length lines and electrical machinery manufacturing service. No matter what your requirements are, our extensive know-how and experience assure you a satisfactory result. We put our most effort to offer good quality, satisfied service, competitive price, timely delivery to our valued customers. Upload your designs files & tell us important details about your project. Once you accept our quote, begin working with our team to make your ideas a reality. Your custom manufactured parts are delivered straight to your doorstep. CANWIN transform and upgrade traditional industries as an opportunity to deepen the ” one belt and one road” strategic layout, deepen cooperation with foreign markets.
The materials that can be processed by longitudinal shear equipment include cold-rolled plate, stainless steel plate, aluminum plate, galvanized plate and color coated plate. However, for different materials, there are certain differences in the strength of blade materials, so as to obtain good cutting effect. Canwin slitting line supplier & manufacturer focus on the internal management and opens up the market.We continuously achieve development in the competition based on strong technical capability, high-quality products, and comprehensive and thoughtful services.
Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. Read even more info at canwindg.com
As a professional laser machine manufacturer & supplier, Canwin specialized in laser machine manufacturing, including laser welding machines and laser cutting machines.Continuous fiber laser hand-held welding equipment is a special equipment for metal processing such as hardware, building materials and handicrafts launched by CANWIN. Small equipment, easy to move and handling, flexible and convenient operation, can realize outdoor welding, suitable for all kinds of complex sheet metal hardware welding. Welding efficiency is fast.
Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.